Part D Technical Data, Measuring Principle and Block Diagram Sect. 12

05/2002

IFC 210 E

89

12

%ORFNGLDJUDP²VLJQDOFRQYHUWHU,)&(

The standard

outstanding accuracy

practice-oriented standard equipment,
current and pulse output (galvanically
isolated)

status and/or control input, adjustable
for numerous tasks: limit switch,
direction indication, error messages,
external initiation of functions, etc.

IMoCom bus, suitable for numerous
internal and external tasks

simplified, standard KROHNE operator
control concept

low power consumption

c

Printed circuit board ADC/FSV

overdrive-proof signal processing, processes flow rate
peaks up to 20 m/s and more, fast and accurate

digital signal processing and sequence control

patented, high-resolution analog/digital converter,
digitally controlled and monitored

input amplifier with facility for voltage grading of the
signalling core shield (bootstrap)

high signal-to-noise ratio through low-loss field current
supply with high frequencies and high currents

pulsed DC current, electronically controlled, for
supplying the magnetic coils in the primary head

customer parameters and internal calibration data are
filed in separate EEPROMs (easily replaceable in the
event of a service)

d

Printed circuit board: display/operator control unit

large illuminated graphic LC display

5 keys for operation of the signal converter

connection to the internal IMoCom bus

distribution of general signals, such as IMoCom bus,
supply power, etc..

e

IMoCom bus plug for connection of external control and

testing equipment, such as adapters and CONFIG software for
operator control via MS-DOS PC

f

Printed circuit board I/O-HART®, outputs and inputs

All outputs and inputs galvanically isolated

Current output I

for active or passive operation

converts the digital output signal from microprocessor
µP into a proportional current

Pulse output P

for electronic totalizers up to max. 10 kHz

for electromechanical totalizers up to max. 50 Hz

KROHNE-specific integrated circuit KSA 04 for fine
quantization of the output signals over a wide dynamic
range

Binary output and input B1 and B2

any output/input combination selectable

status output for limit value, error detection, flow
direction in F/R mode, etc.

control input for totalizer and error resets, also for
holding outputs or setting to “zero“

g

Plug-in module slots for upgrading or retrofitting the

signal converter

RS 485 interface module

GTEX module for Ex-i operation of the signal converter
outside hazardous areas

Further modules in preparation

Graphik

LCD-Display

5 keys

EEPROM

EEPROM