beautypg.com

2 full-scale range q – KROHNE IFC 210 E-EEx EN User Manual

Page 85

background image

Part D Technical Data, Measuring Principle and Block Diagram Sect. 10.2

05/2002

IFC 210 E

85

10.2 Full-scale range Q

100%

Full-scale range Q

100%

Flow rate Q = 100%

6 liter/hr up to 86 860 m

3

/hr, (0.03 – 401 000 US Gal/min),

adjustable required,

equivalent flow velocity 0.3 - 12 m/s (1 - 40 ft/s)

Unit m

3

/hr, Liter/Sec, US gallons/min or user-defined unit,

e.g. Liter/day or US MGal/day


Flow table
v = flow velocity in m/s

Meter size

Full-scale range Q

100%

in m

3

/hr

Q

100%

in US Gal/min

DN

v = 0.3 m/s

v = 1 m/s

v = 12 m/s

v = 1 ft /s

v = 40 ft /s

mm inch

(minimum)

(maximum)

(minimum) (maximum)

2.5

1

/

10

0.0053

0.0177

0.2121

0.0245

0.979

4

1

/

8

0.0136

0.4520

0.5429

0.0383

1.530

6

1

/

4

0.0306

0.1018

1.222

0.1530

6.120

10

3

/

8

0.0849

0.2827

3.392

0.3735

14.93

15

1

/

2

0.1909

0.6362

7.634

0.8405

33.61

20

3

/

4

0.3393

1.131

13.57

1.494

59.75

25

1

0.5302

1.767

21.20

2.334

93.34

32

-

0.8686

2.895

34.74

3.824

153.0

40

1

1

/

2

1.358

4.524

54.28

5.979

239.0

50

2

2.121

7.069

84.82

9.339

373.5

65

-

3.584

11.95

143.3

15.78

630.9

80

3

5.429

18.10

217.1

23.90

955.6

100

4

8.483

28.27

339.2

37.35

1493

125

-

13.26

44.18

530.1

37.35

2334

150

6

19.09

63.62

763.4

84.05

3361

200

8

33.93

113.1

1357

149.43

5975

250

10

53.02

176.7

2120

233.4

9334

300

12

76.35

254.5

3053

336.2

13442

400

16

135.8

452.4

5428

597.9

23899

500

20

212.1

706.9

8482

933.9

37345

600

24

305.4

1018

12215

1345

53781

700

28

415.6

1385

16625

1919

76760

800

32

542.9

1810

21714

2507

100272

900

36

662.8

2290

26510

3173

126904

1000

40

848.2

2827

33929

3917

156672

1200

48

1221 4072 48858

5640

225608

1400

56

1663 5542 66501

7677

307080

1600

64

2171 7238 86859

10027

401080


This manual is related to the following products: