beautypg.com

KROHNE IFC 210 E-EEx EN User Manual

Page 56

background image

Sect. 6.1 Part C Special applications, functional checks, service, and order numbers

IFC 210 E

05/2002

56

6.1.3 Technical data and terminal assignment

Supply power

Terminals

L or 1L: z28

Plug

XB

N or 0L: z32 Plug

XB

24 DC / AC

U

N

= 24 V DC +30% / -25%, 15 W

U

N

= 24 V AC +10% / -15%, 20 VA

I

N

1.6 AT internal fuse protection

100 ... 230 V AC

U

N

= 100 ... 230 V AC +10% / -15%, 25 VA

I

N

0.8 AT internal fuse protection

Protective conductor/equipotential
bonding

PE / PA

Terminals

d14, d16, d18, d20

Plug XB

d2 ... d12, d22 ... d32

plug XB (optional)

Signalling circuits

Outputs and inputs

Terminals:

Analog

d16, d18, z18

Plug XC:

Binary

d24, d26, z26

Plug XC

Pulses

d32, z32

Plug XC

RS 485

d16, d18, d20, d22, d24

Plug XC (optional)

DC voltage

U

N

(DC)

50 V (connection to devices with

AC voltage

U

N

(AC)

25 V operating voltages up to 250 V)

Field circuit

Terminals

Core 7

d30

Plug XA

Core 8

d32

Plug XA

Frequency-controlled DC voltage

U

N

40 V

Internal fuse protection

I

N

160 mAF

Electrode circuit

in Intrinsic Safety type of protection EEx ib IIC

Terminals:

Signal cores 2, 3

Z6, z10

Plug XA

Shield

20,

30

(BTS

conductor

only)

D6, d10

Plug XA

Shield 1

d8, z8

Plug XA

Outer shield

d2, z2, d4, z4

Plug XA

Peak values

U

0

18 V

(cumulative value)

I

0

40 mA

(cumulative value)

P

0

80 mW

The intrinsically safe electrode circuit is safety-separated (isolated) from the non-intrinsically safe
circuits up to a peak nominal voltage of 375 V.

Ambient temperature

max. allowable –20 to +55°C


This manual is related to the following products: