KROHNE IFC 210 E-EEx EN User Manual
Page 40
Sect. 5.5
Part B IFC 210 Signal converter
IFC 210 E
05/2002
40
5.5
Display (Fct. 1.04)
Fct. 1.04 Display
Press
→
key.
Contrast = set required contrast
•
Range adjustable from +15 (high contrast) to –15 (= low contrast)
Change setting with
↑
or
↓
key,
Press
↵
key to transfer to subfunction “flow“.
Flow = set required flow unit and number format
•
Auto
(= exponent notation)
•
# . ####
•
## . ##
•
### . #
Change setting with
↑
or
↓
key,
•
####
Transfer to Unit Selection with
→
key.
•
m
3
/hr
(cubic metres per hour)
•
Liter/Sec
(litres per second)
•
US Gal/min
(US gallons per minute)
•
User-defined unit, factory setting = Liter/hr (litres per hour) or US MGal/day , see Sect. 5.17
Select with
↑
or
↓
key.
Press
↵
key to change to subfunction “totalizer”.
Totalizer = set required totalizer unit and number format
•
Auto
(= exponent notation)
•
# . ######
•
## . #####
•
### . ####
•
#### . ###
•
##### . ##
•
###### . #
Change setting with
↑
or
↓
key,
•
#######
Transfer to Unit Selection with
→
key.
•
m
3
(cubic metres)
•
Liter
(litres)
•
US. Gal
(US gallons)
•
User-defined unit, factory setting = Liter (litres) or US MGal/day , see Sect. 5.17
Select with
↑
or
↓
key.
Press
↵
key to change to subfunction “messages”.