KROHNE IFC 210 E-EEx EN User Manual
Page 59
Part C Special applications, functional checks, service, and order numbers Sect. 6.2
05/2002
IFC 210 E
59
Settings and operation
Fct.
Parameter
Point-to-point mode
Multidrop mode
1.05 Function
1 CORRECT. or 2 CORRECT.
OFF
Range I
4-20 mA or I
0%
≥
4 mA
I
0%
≥
4 mA
3.09 Communication
HART HART
Address
0
01, 02, 03 ..... 15
(use one address at
one time only)
Operation
Current output
active or passive
passive only
For further information on setting the signal converter refer to chapters 4 and 5.
HART
®
operating tools / Device Description (DD)
The signal converter can be operated either via its local operator interface or by means of the
HART
®
communicator, which is available from KROHNE.
Operator control by means of the HART
®
communicator requires a device description (DD) which
we can load for you into the communicator. We can, of course, also load the DDs of all
manufacturers who have filed their DDs with the HART
®
Communication Foundation.
If you wish to use the signal converter in your operating tool, for example, please ask for the
description of the HART
®
command used so that you can address the complete signal converter
functionality via HART
®
.