Technical data – KROHNE IFC 100 Converter EN User Manual
Page 82
8
TECHNICAL DATA
82
IFC 100
www.krohne.com
07/2010 - 4000041004 - MA IFC 100 R04 en
Time constant
Time constant
Time constant
Time constant
Function
The time constant corresponds to the elapsed time until 67% of the end value has
been reached according to a step function.
Settings
Set in increments of 0.1.
0…100 s
Status output / limit switch
Status output / limit switch
Status output / limit switch
Status output / limit switch
Function and settings
Adjustable as automatic measuring range conversion, display of flow direction,
counter overflow, error, switching point or empty pipe detection
Valve control with activated dosing function
Status and/or control: ON or OFF
Operating data
Operating data
Operating data
Operating data
Passive
U
ext
≤ 32 VDC
I ≤ 100 mA
open:
I ≤ 0.05 mA at U
ext
= 32 VDC
closed:
U
0, max
= 0.2 V at I ≤ 10 mA
U
0, max
= 2 V at I ≤ 100 mA
Modbus (in preparation)
Modbus (in preparation)
Modbus (in preparation)
Modbus (in preparation)
Description
Modbus RTU, Master / Slave, RS485
Address range
1…247
Broadcast
Supported with function code 16
Supported Baudrate
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Baud
Approvals and certificates
CE
The device fulfils the statutory requirements of the EC directives. The manufacturer
certifies that these requirements have been met by applying the CE marking.
Non-Ex
Standard
Hazardous areas
Hazardous areas
Hazardous areas
Hazardous areas
ATEX
Optional (OPTIFLUX 2100 C and OPTIFLUX 4100 C only)
Optional (OPTIFLUX 2100 C and OPTIFLUX 4100 C only)
Optional (OPTIFLUX 2100 C and OPTIFLUX 4100 C only)
Optional (OPTIFLUX 2100 C and OPTIFLUX 4100 C only)
II 2 G Ex e [ia] mb IIC T4 (DN10...20; DN200...300; DN350...3000)
II 2 G Ex d e [ia] mb IIC T4 (DN25...150)
II 2 G Ex e [ia] mb q T4/T3 (DN25...150; DN200...300)
II 2 D Ex tD A21 IP64 T120°C (all nominal sizes)
Option (only version W)
Option (only version W)
Option (only version W)
Option (only version W)
II 2 G Ex e [ia] mb IIC T4
II 2 D Ex tD A21 IP64 T135°C
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
Shock and vibration resistance
IEC 68-2-3
Electromagnetic compatibility
(EMC)
2004/108/EC in conjunction with EN 61326-1 (A1, A2)
European Pressure Equipment
Directive
PED 97/23 (only for compact versions)
NAMUR
NE 21, NE 43, NE 53
.book Page 82 Friday, July 9, 2010 12:29 PM