No.

Function

Settings / descriptions

C4 I/O HART

C4

I/O HART

Selection / display of the 4 dynamic variables (DV) for HART

®

.

The HART

®

current output (terminal A basic I/Os) always has a fixed link to

the primary variables (PV). Fixed links of the other DVs (1-3) are only

possible if one additional analogue output (frequency) is available; if not, the

measurement can be freely selected from the following list: see Fct. A4.1

"measurement".

…

stands for 1, 3 or 4

X stands for connection terminals A, C or D

C4.1

PV is

Current output (primary variable)

C4.2

SV is

(secondary variable)

C4.3

TV is

(tertiary variable)

C4.4

4V is

(4th variable)

C4.5

HART units

Changes units of DVs (dynamic variables) in the display

Break: return with ^ key

HART display

®

: copies the settings for the display units to the settings for

DVs

Standard: sets factory defaults for DVs

C4.….1

current out X

Shows the current analogue measured value of the linked current output.

The measurement cannot be changed!

C4.….1

frequency out X

Shows the current analogue measured value of the linked frequency output,

if present. The measurement cannot be changed!

C4.….1

HART dynamic var.

Measurements of the dynamic variables for HART

®

.

Linear measurements: volume flow / mass flow / diagnosis value / flow

speed / coil temperature / conductivity

Digital measurements: counter 1 / counter 2 / operating hours

No.

Function

Settings / descriptions

C5 device

C5.1 device info

C5.1

device info

Grouping of all functions that have no direct effect on the measurement or

any output.

C5.1.1

Tag

Settable characters (max. 8 digits):

A…Z; a…z; 0…9; / - , .

C5.1.2

C number

CG number, non-alterable (input/output versions)

C5.1.3

device serial no.

Serial no. of the system.

C5.1.4

electronic serial no.

Serial no. of the electronic assembly, cannot be changed.

C5.1.5

SW.REV.MS

Serial no. of the circuit board, version no. of the main software, production

date of the circuit board

C5.1.6

Electronic Revision ER

Reference identification number, electronic revision and production date of

the device; includes all hardware and software changes

.book Page 64 Friday, July 9, 2010 12:29 PM