ELECTRICAL CONNECTIONS

4

43

IFC 100

www.krohne.com

07/2010 - 4000041004 - MA IFC 100 R04 en

Status output / limit switch passive

• U

ext

≤ 32 VDC

• I ≤ 100 mA
• R

L, max

= 10 kΩ

R

L, min

= (U

ext

- U

0

) / I

max

• open:

I ≤ 0.1 mA at U

ext

= 5 V

I ≤ 0.5 mA at U

ext

= 24 V

I ≤ 0.7 mA at U

ext

= 32 V

closed:
U

0, max

= 0.8 V at I ≤ 1 mA

U

0, max

= 1.5 V at I ≤ 10 mA

U

0, max

= 3.5 V at I ≤ 100 mA

• The output is closed when the device is de-energized.

CAUTION!
Observe connection polarity.

Figure 4-19: Status output / limit switch passive S

p