Description of hart interface – KROHNE IFC 100 Converter EN User Manual
Page 103
DESCRIPTION OF HART INTERFACE
9
103
IFC 100
www.krohne.com
07/2010 - 4000041004 - MA IFC 100 R04 en
4 information
1 liner / 2 electr. material /
3 serial no. sensor
Rd
/ 4 V no. sensor
Rd
/
5 sensor electr. info
5 sensor limits
1 volume flow
1 upper snsr limit
Rd
/
2 lower snsr limit
Rd
/
3 minimum span
Rd
2 mass flow
3 flow speed
4 conductivity
5 coil temperature
2 I/O
1 hardware
1 terminals A
Cust
/ 2 terminals C
Cust
/ 3 terminals D
Cust
2 A
3 C
4 D
current output
current output
current output
current output
Opt
Opt
Opt
Opt
:
1 range 0%
Cust
/ 2 range 100%
Cust
/
3 extended range min
Cust
/ 4 extended range max
Cust
/
5 error current
Cust
/ 6 error condition
Cust
/
7 measurement
Cust
/ 8 range min
Cust
/
9 range max
Cust
/ 10 polarity
Cust
/
11 limitation min
Cust
/ 12 limitation max
Cust
/
13 lfc threshold
Cust
/ 14 lfc hysteresis
Cust
/
15 time constant
Cust
/ 16 special function
Cust
/
17 rc threshold
Opt, Cust
/ 18 rc hysteresis
Opt, Cust
/
19 information
frequency output
frequency output
frequency output
frequency output
Opt
Opt
Opt
Opt
:
1 pulse shape
Cust
/ 2 pulse width
Cust
/
3 100% pulse rate
Cust
/ 4 measurement
Cust
/
5 range min
Cust
/ 6 range max
Cust
/
7 polarity
Cust
/ 8 limitation min
Cust
/
9 limitation max
Cust
/ 10 lfc threshold
Cust
/
11 lfc hysteresis
Cust
/ 12 time constant
Cust
/
13 invert signal
Cust
/ 14 special function
Opt, Cust
/
15 information
pulse output
pulse output
pulse output
pulse output
Opt
Opt
Opt
Opt
:
1 pulse shape
Cust
/ 2 pulse width
Cust
/
3 max. pulse rate
Cust
/ 4 measurement
Cust
/
5 pulse value unit / 6 value p. pulse /
7 polarity
Cust
/ 8 lfc threshold
Cust
/
9 lfc hysteresis
Cust
/ 10 time constant /
11 invert signal
Cust
/ 12 special function
Opt, Cust
/
13 information
status output
status output
status output
status output
Opt
Opt
Opt
Opt
:
1 mode / 2 output A
Opt
/
2 output C
Opt
/ 2 output D
Opt
/
3 invert signal / 4 information
limit switch
limit switch
limit switch
limit switch
Opt
Opt
Opt
Opt
:
1 measurement / 2 threshold / 3 hysteresis /
4 polarity / 5 time constant /
6 invert signal / 7 information
3 I/O counter
1 counter 1
1 funct. of counter
Cust
/ 2 measurement
Cust, Rd
/
3 select measurement
Opt, Cust
/ 4 lfc threshold
Opt, Cust
/
5 lfc hysteresis
Opt, Cust
/ 6 time constant
Opt, Cust
/
7 preset value
Opt, Cust
/ 8 reset counter
Opt, Cust
/
9 set counter
Opt, Cust
/ 10 information
2 counter 2
4 I/O HART
1 PV is
Rd
/ 2 SV is / 3 TV is / 4 4V is / 5 D/A trim
Cust
/
6 apply values
Cust
/ 7 HART units
.book Page 103 Friday, July 9, 2010 12:29 PM