Table 3-5. square waveform frequency vs. points, 3 waveform specifications, Figure 3-7. sample waveform – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual
Page 86: 4 executing a waveform, Waveform specifications -24, Executing a waveform -24, Sample waveform -24, Square waveform frequency vs. points -24
![background image](/manuals/367930/86/background.png)
3-24
BOP-1K-GL 022814
3.5.7.3
WAVEFORM SPECIFICATIONS
Refer to Table 1-2 for specifications applicable to waveforms created using LIST commands.
FIGURE 3-7. SAMPLE WAVEFORM
3.5.7.4
EXECUTING A WAVEFORM
These segments are programmed using the LIST:CURR:APPLy (PAR. B.57) or
LIST:VOLT:APPLy (PAR. B.79) commands. The details of the waveform segments are defined
in Table 3-6. Once the waveform segments are added to the list, the list is executed by sending
either CURR:MODE LIST (PAR. B.27) or VOLT:MODE LIST (PAR. B.94).
TABLE 3-5. SQUARE WAVEFORM FREQUENCY VS. POINTS
Frequency
(See Note)
Total Points
Frequency
(See Note)
Total Points
From
To
From
To
0.02Hz
1.8Hz
3840
43.51Hz
58.0Hz
120
1.81Hz
2.7Hz
2880
58.01Hz
72.5Hz
90
2.71Hz
4.0Hz
1920
72.51Hz
87.0Hz
72
4.01
5.4Hz
1280
87.01Hz
108.7Hz
60
5.41
7.2Hz
960
108.71Hz
145.0Hz
48
7.21Hz
10.8Hz
720
145.2.9Hz
174.0Hz
36
10.81
16.3Hz
480
174.1Hz
217.5Hz
30
16.31Hz
21.7Hz
320
217.6Hz
261.0Hz
24
21.71Hz
27.1Hz
240
261.1Hz
435.0Hz
20
27.11Hz
32.6Hz
192
435Hz
652.5Hz
12
55.5Hz
66.5Hz
160
653
1000
10
NOTE: Time interval per point is inversely proportion to frequency variation within the range.