B.88 [source:]voltage[:level]:limit[:both] command, B.89 [source:]voltage[:level]:limit[:both]? query, B.87 – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual
Page 155: Sour, B.88, B.89, B.90, B.91, B.92, B.93
BOP-1KW-GL 022814
B-27
B.87 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? QUERY
VOLT?
Syntax:
Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]? {MIN | MAX}
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? {MIN | MAX}
Description: Identifies programmed voltage, maximum allowable voltage, or minimum voltage. The VOLT?
query returns the programmed value of voltage. Actual output voltage will depend on load conditions.
The VOLT?MAX query returns the maximum voltage allowed for a particular model. VOLT? MIN
returns minimum voltage allowed for power supply (always negative). Related Commands: VOLT.
(See example, Figure B-1.)
B.88 [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH] COMMAND
VOLT:LIM[:BOTH]
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH]
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH]
where
Description: Establishes the software limit
negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.89 [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH]? QUERY
VOLT:LIM[:BOTH]?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH]?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:[:BOTH]?
Returns
Description: Identifies the software limit value for both positive and negative output voltage specified by the user.
B.90 [SOURce:]VOLTage[:LEVel]:LIMit:NEGative COMMAND
VOLT:LIM:NEG
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative
where
Description: Establishes the software limit
negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.91 [SOURce:]VOLTage[:LEVel]:LIMit:NEGative? QUERY
VOLT:LIM:NEG?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative?
Description: Identifies the software limit value for negative output voltage specified by the user.
B.92 [SOURce:]VOLTage[:LEVel]:LIMit:POSitive COMMAND
VOLT:LIM:POS
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:POS
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive
where
Description: Establishes the software limit
itive output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to save
for power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.93 [SOURce:]VOLTage[:LEVel]:LIMit:POSitive? QUERY
VOLT:LIM:POS?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:POS?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive?
Description: Identifies the software limit value for positive output voltage specified by the user.