B.136 SYSTem:KEYBoard? QUERY

SYST:KEYB?

Syntax:

Short Form: SYST:KEYB?

Long Form: SYSTem:KEYBoard?

Returns: 1 or 0

Description: Limited functionality; included for compatibility with other Kepco products. (Identifies the state of a key-

pad: locked = 1 or unlocked = 0.)

B.137 SYSTem:PASSword:CENable COMMAND

SYST:PASS:CEN

Syntax:

Short Form: SYST:PASS:CEN
Long Form: SYSTem:PASSword:CENable

Description: Sets the password enable state if the matches the current password. This command allows

CALibrate commands to operate.

B.138 SYSTem:PASSword:CDISable COMMAND

SYST:PASS:CDIS

Syntax:

Short Form: SYST:PASS:CDIS

Long Form: SYSTem:PASSword:CDISable

Description: Clears the password enable state.

B.139 SYSTem:PASSword:NEW COMMAND

SYST:PASS:NEW

Syntax:

Short Form: SYST:PASS:NEW ,
Long Form: SYSTem:PASSword:NEW ,

Description: Establishes new password. The old (current) password is checked, then replaced by the new pass-

word. (See example, Figure B-13.) See PAR. 3.5.5.2 and Figure 3-6 for special programming consid-
erations.

B.140 SYSTem:PASSword:STATe? QUERY

SYST:PASS:STAT?

Syntax:

Short Form: SYST:PASS:STAT?

Long Form: SYSTem:PASSword:STATe?

Return Value: 0 or 1

Description: Returns a 1 if the password state is enabled or a 0 if it is disabled.

B.141 SYSTem:REMote COMMAND

SYST:REM

Syntax:

Short Form: SYST:REM {ON | OFF} or {1 | 0}
Long Form: SYSTem:REMote {ON | OFF} or {1 | 0}

Description: Used during serial (RS 232) communication to set the unit to remote (1 or ON) or local (0 or

OFF) mode. This command must be issued prior to commands that affect the power supply output
(e.g., VOLT 10;:OUTP ON) to ensure the unit is in remote mode. See PAR. 3.6.4.3 and Figure B-12.

B.142 SYSTem:REMote? QUERY

SYST:REM?

Syntax:

Short Form: SYST:REM?

Long Form: SYSTem:REMote?

Return Value: {1 | 0}

Description: Identifies whether unit it in remote mode (1) or local mode (0) during serial (RS 232) communi-

cation. See PAR. 3.6.4.3 and Figure B-12.

FIGURE B-12. SETTING THE UNIT TO REMOTE MODE VIA SERIAL (RS 232) PORT

*IDN?

Unit responds with KEPCO,BOP 50-20,E1234,1.66 (typical).

OUTP?

Unit responds with 0 indicating output is off

SYST:REM?

Unit responds with 0 indicating unit is in local mode.

SYST:REM 1

Puts unit in remote mode.

OUTP ON

Enables output

OUTP?

Unit responds with 1 (output on).

SYST:REM 0

Unit set to local mode.