B.136 system:keyboard? query, B.137 system:password:cenable command, B.138 system:password:cdisable command – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual
Page 164: B.139 system:password:new command, B.140 system:password:state? query, B.141 system:remote command, B.142 system:remote? query, B.136, Syst, B.137
B-36
BOP-1KW-GL 022814
B.136 SYSTem:KEYBoard? QUERY
SYST:KEYB?
Syntax:
Short Form: SYST:KEYB?
Long Form: SYSTem:KEYBoard?
Returns: 1 or 0
Description: Limited functionality; included for compatibility with other Kepco products. (Identifies the state of a key-
pad: locked = 1 or unlocked = 0.)
B.137 SYSTem:PASSword:CENable COMMAND
SYST:PASS:CEN
Syntax:
Short Form: SYST:PASS:CEN
Long Form: SYSTem:PASSword:CENable
Description: Sets the password enable state if the
CALibrate commands to operate.
B.138 SYSTem:PASSword:CDISable COMMAND
SYST:PASS:CDIS
Syntax:
Short Form: SYST:PASS:CDIS
Long Form: SYSTem:PASSword:CDISable
Description: Clears the password enable state.
B.139 SYSTem:PASSword:NEW COMMAND
SYST:PASS:NEW
Syntax:
Short Form: SYST:PASS:NEW
Long Form: SYSTem:PASSword:NEW
Description: Establishes new password. The old (current) password is checked, then replaced by the new pass-
word. (See example, Figure B-13.) See PAR. 3.5.5.2 and Figure 3-6 for special programming consid-
erations.
B.140 SYSTem:PASSword:STATe? QUERY
SYST:PASS:STAT?
Syntax:
Short Form: SYST:PASS:STAT?
Long Form: SYSTem:PASSword:STATe?
Return Value:
Description: Returns a 1 if the password state is enabled or a 0 if it is disabled.
B.141 SYSTem:REMote COMMAND
SYST:REM
Syntax:
Short Form: SYST:REM {ON | OFF} or {1 | 0}
Long Form: SYSTem:REMote {ON | OFF} or {1 | 0}
Description: Used during serial (RS 232) communication to set the unit to remote (1 or ON) or local (0 or
OFF) mode. This command must be issued prior to commands that affect the power supply output
(e.g., VOLT 10;:OUTP ON) to ensure the unit is in remote mode. See PAR. 3.6.4.3 and Figure B-12.
B.142 SYSTem:REMote? QUERY
SYST:REM?
Syntax:
Short Form: SYST:REM?
Long Form: SYSTem:REMote?
Return Value: {1 | 0}
Description: Identifies whether unit it in remote mode (1) or local mode (0) during serial (RS 232) communi-
cation. See PAR. 3.6.4.3 and Figure B-12.
FIGURE B-12. SETTING THE UNIT TO REMOTE MODE VIA SERIAL (RS 232) PORT
*IDN?
Unit responds with KEPCO,BOP 50-20,E1234,1.66 (typical).
OUTP?
Unit responds with 0 indicating output is off
SYST:REM?
Unit responds with 0 indicating unit is in local mode.
SYST:REM 1
Puts unit in remote mode.
OUTP ON
Enables output
OUTP?
Unit responds with 1 (output on).
SYST:REM 0
Unit set to local mode.