OUTPUT CHARACTERISTICS (Continued)

Error sensing

0.25V or 1% of voltage rating per

wire (whichever is less)

Above rated output voltage(2)

Transient recovery in
voltage mode

maximum excursion

5% of nominal output

nominal voltage, 50% load step

Recovery time

350

µ

sec

Return within 1% of set voltage

Output isolation voltage

d-c or p-p

300V (500V for BOP 10-100GL)

Output to chassis ground

d-c leakage current

0.1mA @ 300V

(0.1mA @ 500V for BOP 10-100GL)

GND-NET to GND link not installed. (3)

Series operation

Master/slave

Maximum of 2 identical units. (4)(5)

Parallel operation

Master/slave

Maximum of 2 identical units (4)(5)
(maximum of 3 for BOP 10-100GL)

Output Protection
limiting

Analog

Voltage and current limited in four quadrants, adjustable

between 10% and 101% of EO

NOM

or IO

NOM

Digital Voltage and current limited in four quadrants, adjustable between ±Internal minimum

EO

MIN

or IO

MIN

(box) (see Figure 1-3) and ±1.01 EO

NOM

or IO

NOM

.

Output Stage Protection

Output overvoltage/overcurrent

Heatsink overtemperature,

switchers overcurrent

Triggers latched shutdown protection of the
output module and PFC stage. Recover by
cycling power off, then on.

Input Stage Protection (PFC)

Internal overvoltage, undervoltage,

overcurrent, heat sink

overtemperature, fan inoperative

Input circuit breaker overcurrent

Trips circuit breaker to shut off unit

Small signal
Bandwidth for main
channel (analog or
digital)

voltage channel

1 KHz minimum

Into nominal resistive load, 10% of rating

current channel

800 Hz minimum

Into short circuit, 10% of rating

Rise/Fall time

voltage channel

475

µ

Sec

Into nominal resistive load, measured from 10
to 90%, from 0 to ±100% of rating

current channel

500

µ

Sec

Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating

External limit channels update rate

100mS max

Voltage or current, positive and negative limit
values

(2) Remote error sensing applies to the main voltage channel. Feedback for the ±voltage limit channels is supplied locally

from the power terminals. Consult factory for a remote sensing solution applicable to the voltage limit channels.

(3) With GND-NET to GND link installed: 0.55mA at 300V (0.91mA at 500V for BOP 10-100GL).
(4) Consult factory to configure more than two units in series or parallel (three units for BOP 10-100GL in parallel).
(5) For multiple unit configurations, automatic shutdown upon accidental removal of the cable at the Master PAR/SER IN

PROTECT PORT can be implemented with a simple internal modification. Consult factory for details.

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION