BOP-1K-GL 022814

• If S3 is set to 101xx (x = set as desired, S3-3 = 1, S3-4 = 0, S3-5 = 1), –V Protect Max

and –C Protect Max are internally set to maximum (1.01 x nominal (rated) values. +V
Protect Max and +C Protect Max are Internally set to min. (box).

• If S3 is set to 110xx (x = set as desired, S3-3 = 0, S3-4 = 1, S3-5 = 1), +V Protect Max

and +C Protect Max are internally set to maximum (1.01 x nominal (rated) values. –V
Protect Max and –C Protect Max are Internally set to min. (box).

• If S3 is set to 111xx (x = set as desired, S3-3 = 1, S3-4 = 1, S3-5 = 1), ±V Protect Max

and ±C Protect Max are internally set to maximum (1.01 x nominal (rated) values.

Once the unit is powered up, main channel mode can be controlled by the CURR:PROT:MODE
(see PAR. B.31) and VOLT:PROT:MODE (see PAR. B.98) commands.

• Sending VOLT:PROT:MODE FIXED allows the voltage protect limits to be controlled by

VOLT:PROT:LIM commands and sending CURR:PROT:MODE FIXED allows the current
protect limits to be controlled by CURR:PROT:LIM commands

• Sending VOLT:PROT:MODE EXT allows the voltage protect limits to be controlled by

pins 6 and 14 of the Analog I/O port. Sending CURR:PROT:MODE EXT allows the cur-
rent protect limits to be controlled by pins 5 and 13 of the Analog I/O port.

• Sending VOLT:PROT:MODE LESS allows the voltage protect limits to be controlled by

the lesser absolute value between that selected by the digital VOLT:PROT:LIM com-
mands and the analog voltage on pins 6 and 14 of the Analog I/O port (see PAR. 3.4.2.1
for details).

• Sending CURR:PROT:MODE LESS allows the current protect limits to be controlled by

the lesser absolute value between that selected by the digital CURR:PROT:LIM com-
mands and the analog voltage on pins 5 and 13 of the Analog I/O port (see PAR. 3.4.2.1
for details).

3.4

ANALOG REMOTE MODE PROGRAMMING

The recommended method for asserting Analog control requires that the unit be powered up
with power-up switches S3-1 through S3-5 set to 00000 (see Figure 2-2 and Table 2-2). This
sets up the following:

• The main channel is controlled by the external reference at pin 11 of the Analog I/O port

(see Table 2-11).

• The limit channels are controlled by the reference voltages at pins 5, 6, 13 and 14 of the

Analog I/O port (only two pins are active, determined by which limit channel is
active) (see Table 2-11).

• The mode (voltage/current) is determined by the state of pin 2 of the Analog I/O port