beautypg.com

B.22 [source:]current[:level]:limit[:both]? query, B.23 [source:]current[:level]:limit:neg command, B.24 [source:]current[:level]:limit:neg? query – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual

Page 137: B.25 [source:]current[:level]:limit:pos command, B.26 [source:]current[:level]:limit:pos? query, B.22, Sour, B.23, B.24, B.25

background image

BOP-1KW-GL 022814

B-9

B.22 [SOURce:]CURRent[:LEVel]:LIMit[:BOTH]? QUERY

CURR:LIM[:BOTH]?

Syntax:

Short Form: [SOUR:]CURR[:LEV]:LIM[:BOTH]?
Long Form: [SOURce:]CURRent[:LEVel]:LIMit[:BOTH]?
Returns ,

Description: Identifies the positive software limit, followed by the negative software limit value of output current that

the unit can source or sink.

B.23 [SOURce:]CURRent[:LEVel]:LIMit:NEG COMMAND

CURR:LIM:NEG

Syntax:

Short Form: [SOUR:]CURR[:LEV]:LIM:NEG
Long Form: [SOURce:]CURRent[:LEVel]:LIMit:NEGative

Description: Establishes the negative software limit for output current, i.e., sets the maximum value of out-

put current that the unit will be allowed to source (quadrant 3, Figure 1-3) or sink (quadrant 2) to the
value specified by the user. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR. 3.5.5.2
and Figure 3-6 for special programming considerations.

B.24 [SOURce:]CURRent[:LEVel]:LIMit:NEG? QUERY

CURR:LIM:NEG?

Syntax:

Short Form: [SOUR:]CURR[:LEV]:LIM:NEG?
Long Form: [SOURce:]CURRent[:LEVel]:LIMit:NEGative?
Returns

Description: Identifies the negative software limit value of output current that the unit can source (quadrant 3, Fig-

ure 1-3) or sink (quadrant 2).

B.25 [SOURce:]CURRent[:LEVel]:LIMit:POS COMMAND

CURR:LIM:POS

Syntax:

Short Form: [SOUR:]CURR[:LEV]:LIM:POS
Long Form: [SOURce:]CURRent[:LEVel]:LIMit:POSitive
where is between zero and the rated (nominal) output voltage

Description: Establishes the positive software limit for output current, i.e., sets the maximum value of out-

put current that the unit will be allowed to source (quadrant 1, Figure 1-3) or sink (quadrant 4) to the
value specified by the user. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR. 3.5.5.2
and Figure 3-6 for special programming considerations.

B.26 [SOURce:]CURRent[:LEVel]:LIMit:POS? QUERY

CURR:LIM:POS?

Syntax:

Short Form: [SOUR:]CURR[:LEV]:LIM:POS?
Long Form: [SOURce:]CURRent[:LEVel]:LIMit:Positive?
Returns

Description: Identifies the positive software limit value of output current that the unit can source (quadrant 1, Figure

1-3) or sink (quadrant 4).