beautypg.com

Table 1-2. bop general specifications, Bop general specifications -2 – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual

Page 20

background image

1-2

BOP-1K-GL 022814

TABLE 1-2. BOP GENERAL SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

CONDITION

INPUT CHARACTERISTICS

A-C Voltage

nominal

230 Va-c

Single phase, or between two phases of a 3-
phase system

range

176 - 264 Va-c

Frequency

nominal

50-60 Hz

range

47 - 63 Hz

Current 176

Va-c

9.5A

maximum

264 Va-c

6.4A

maximum

Power factor

Source

0.99 minimum

nominal output power

Sink

0.97 minimum

Efficiency

65%

minimum, when sourcing

Switching frequency

70 KHz

PFC Stage, 5% tolerance

EMC Compliance

EN61326-1 (1997)

Class A equipment

EMC immunity to:

ESD

EN61000-4-2

Electrostatic discharge

Radiated RF

EN61000-4-3

EFT

EN61000-4-4

Electrical fast transient/burst

Surges

EN61000-4-5

Conducted RF

EN61000-4-6

EMC emissions

Conducted

EN61000-3-2

harmonics

EN61000-3-3

fluctuation & flicker

Conducted

EN55011/CISPR11

0.15 to 30 MHz

Radiated

EN55011/CISPR11

30 to 1000 MHz

Leakage current

3.5 mA

230V a-c, 60 Hz

Insulation coordination

Input

Installation Category II

for TN or TT power systems

Overvoltage Category II

Output

Installation Category II

maximum 300V (500V for BOP 10-100GL)
isolation voltage between each output termi-
nal and chassis ground.

Overvoltage Category II

Pollution degree

2

OUTPUT CHARACTERISTICS

(1)

Type of stabilizer

Voltage-Current, 4 quadrant

Switch mode

Switching frequency

100KHz

Output Stage, 5% tolerance

Source adjustment
range

voltage

-100% to +100% of rating

0 to 50 deg C

current

-100% to +100% of rating

Sink adjustment range

voltage

-100% to +100% of rating

0 to 50 deg C. Recuperated energy is sent
back into line for general reuse.

current

-100% to +100% of rating

(1) Output characteristics are for a single standalone unit.