Table 1-2. bop general specifications, Bop general specifications -2 – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual
Page 20
1-2
BOP-1K-GL 022814
TABLE 1-2. BOP GENERAL SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION
INPUT CHARACTERISTICS
A-C Voltage
nominal
230 Va-c
Single phase, or between two phases of a 3-
phase system
range
176 - 264 Va-c
Frequency
nominal
50-60 Hz
range
47 - 63 Hz
Current 176
Va-c
9.5A
maximum
264 Va-c
6.4A
maximum
Power factor
Source
0.99 minimum
nominal output power
Sink
0.97 minimum
Efficiency
65%
minimum, when sourcing
Switching frequency
70 KHz
PFC Stage, 5% tolerance
EMC Compliance
EN61326-1 (1997)
Class A equipment
EMC immunity to:
ESD
EN61000-4-2
Electrostatic discharge
Radiated RF
EN61000-4-3
EFT
EN61000-4-4
Electrical fast transient/burst
Surges
EN61000-4-5
Conducted RF
EN61000-4-6
EMC emissions
Conducted
EN61000-3-2
harmonics
EN61000-3-3
fluctuation & flicker
Conducted
EN55011/CISPR11
0.15 to 30 MHz
Radiated
EN55011/CISPR11
30 to 1000 MHz
Leakage current
3.5 mA
230V a-c, 60 Hz
Insulation coordination
Input
Installation Category II
for TN or TT power systems
Overvoltage Category II
Output
Installation Category II
maximum 300V (500V for BOP 10-100GL)
isolation voltage between each output termi-
nal and chassis ground.
Overvoltage Category II
Pollution degree
2
OUTPUT CHARACTERISTICS
(1)
Type of stabilizer
Voltage-Current, 4 quadrant
Switch mode
Switching frequency
100KHz
Output Stage, 5% tolerance
Source adjustment
range
voltage
-100% to +100% of rating
0 to 50 deg C
current
-100% to +100% of rating
Sink adjustment range
voltage
-100% to +100% of rating
0 to 50 deg C. Recuperated energy is sent
back into line for general reuse.
current
-100% to +100% of rating
(1) Output characteristics are for a single standalone unit.