B.102, Sour, B.103 – KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual
Page 158: B.104, B.105, B.106, B.107, R. b.104), R. b.106), B.104, b.105
![background image](/manuals/367930/158/background.png)
B-30
BOP-1KW-GL 022814
B.102 [SOURce:]VOLTage[:LEVel]:PROTect:POSitive COMMAND
VOLT:PROT:POS
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:PROT:POS
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:POSitive
where
voltage.
Description: Establishes the positive protection limit for voltage; maximum is 1% greater than rated output voltage.
B.103 [SOURce:]VOLTage[:LEVel]:PROTect:POSitive? QUERY
VOLT:PROT:POS?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:PROT:POS?
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:POSitive?
Returns:
Description: Identifies the positive protection limit for voltage.
B.104 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:BOTH COMMAND
VOLT:PROT:LIM[:BOTH]
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:PROT:LIMit[:BOTH]
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIM[:BOTH
where
voltage.
Description: Establishes the maximum value possible for both the positive and negative protection limits for volt-
age. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR. 3.5.5.2 and Figure 3-6 for spe-
cial programming considerations.
B.105 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit[:BOTH]? QUERY
VOLT:PROT:LIM[:BOTH]?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:PROT:LIM[:BOTH]?
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIMit[:BOTH]?
Returns
Description: Identifies the maximum value possible for protection limits for voltage (positive, negative); maximum is
1% greater than rated output voltage.
B.106 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:NEGative COMMAND
VOLT:PROT:LIM:NEG
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:PROT:LIM:NEG
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:NEGative
where
voltage.
Description: Establishes the minimum (maximum absolute) value possible for the negative protection limit for volt-
age. This may be set up to 1% greater than rated voltage. Requires MEM:UPD (PAR. B.12) to save for
power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.107 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:NEGative? QUERY
VOLT:PROT:LIM:NEG?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:PROT:LIM:NEG?
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:NEGative?
Returns:
Description:Identifies the minimum (maximum absolute) value possible for the negative protection limit
for voltage.