KEPCO BOP-GL 1KW Operator Manual Firmware Ver.3.05 and higher User Manual
Page 28
![background image](/manuals/367930/28/background.png)
1-10
BOP-1K-GL 022814
GENERAL (ENVIRONMENTAL) CHARACTERISTICS
Temperature
operating
0 to +50 deg C
Full rated load
storage
-20 to +85 deg C
Cooling
Two internal fans
intake from the front, exhaust to the rear
Humidity
0 to 95% RH
non-condensing
Shock
20g. 11msec ±50% half sine
non-operating
Vibration
5-10HZ:
10mm double amplitude
3 axes, non-operating
10-55HZ:
2g
3 axes, non-operating
Altitude
sea level to 10,000 feet
Safety Certification
a-c power
UL 3101-1 and EN 6101-1
Pending
PHYSICAL CHARACTERISTICS
Dimensions
English
5.25' X 19" X 21.5"
H X W X D
metric
133.3mm X 482.6mm X 546.1mm
H X W X D
Weight, 1000W models
English
53 lbs
metric
24.1Kg
Connections
Source power
3-pin IEC connector
Load connections
Nickel-plated copper bus bars
With 1/4-20 threaded standoff.
Sensing Output
Terminal Block
7-pin terminal block
Default: 3 links installed for local sensing and
ground network connected.
Analog I/O control
port
15-pin D female
See Figure 2-1, Table 2-11.
PAR/SER CTRL IN
port
8-pin mini DIN connector
PAR/SER CTRL OUT
port
4-pin mini DIN connector
PAR/SER PROT IN
port
8-pin phone jack
PAR/SER PROT OUT
port
8-pin phone jack
EXT PROT port
6-pin phone jack
See Table 2-5
Primary digital port
24-pin GPIB connector
IEEE 488 port - See Table 2-12
Secondary digital
ports
6-pin phone jack
RS 232 port - See Table 2-6
5-pin mini DIN female connector
IEEE 1118 port - See Table 2-3
External Trigger
4-pin stereo audio phone jack
See Table 2-4
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION