TABLE 3-2. VOLTAGE AND CURRENT PARAMETER DEFINITIONS

Term

Definition

To modify

refer to

PAR.

+E

Onom

–E

Onom

The nominal (rated) output voltage of the unit determined by model; e.g. for
a BOP 36-28GL, ±E

Onom

is 36V.

N/A

+I

Onom

–I

Onom

The nominal (rated) output current of the unit determined by model; e.g. for
a BOP 36-28GL, ±I

Onom

is 28A.

N/A

+Voltage
–Voltage

Voltage mode only.

Positive (+) and negative (–) output voltage values

established by remote command.
Range (+): 0 to +Voltage max
Range (–): 0 to –Voltage min

B.86

+Voltage max
–Voltage min

Voltage mode only.

Maximum (positive) and minimum (maximum

negative) voltage that can be set.
Value (+): 0 to +E

Onom

Value (–): 0 to –E

Onom

B.88, B.89,

B.90, B.92

+Current Protect
–Current Protect

Voltage mode only.

Defines maximum (+) current and Minimum (maximum

negative) (–) that unit can source or sink.
Range (+): +Current Protect min to +Current Protect max
Range (–): –Current Protect max to –Current Protect min

B.29, B.30,

B.35, B.33

+Current Protect Max
–Current Protect Min

Voltage mode only.

Maximum setting for +Current Protect and Minimum

(maximum negative) setting for –Current Protect.
Value (+): +Current Protect min to (1.01 x +Current max)
Value (–): –Current Protect max to (1.01 x –Current min)

B.37, B.38,

B.41, B.39

Minimum (box)
+Current Protect Min
–Current Protect Max

Voltage mode only.

Minimum (positive) setting for +Current Protect and

maximum (maximum negative) setting for –Current Protect. Values of ±Cur-
rent Protect between +Current Protect Min and –Current Protect Max (near
zero) are not allowed.This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-3).

N/A

+Voltage Protect
–Voltage Protect

Current mode only.

Maximum positive (+) and minimum (maximum

negative) (–) voltage that can appear at the output.
Range (+): +Voltage Protect min to +Voltage Protect max
Range (–): –Voltage Protect max to –Voltage Protect min

B.96, B.97,

B.102,

B.100

+Voltage Protect Max
–Voltage Protect Min

Current mode only.

Maximum (positive) setting for +Voltage Protect and

Minimum (maximum negative) setting for –Voltage Protect.
Value (+): +Voltage Protect min to (1.01 x +Voltage max)
Value (–): –Voltage Protect max to (1.01 x –Voltage min)

B.104,
B.105,
B.108,

B.106

Minimum (box)
+Voltage Protect Min
–Voltage Protect Max

Current mode only.

Minimum (positive) setting for +Voltage Protect and

maximum (maximum negative) setting for –Voltage Protect. Values of ±Volt-
age Protect between +Voltage Protect Min and –Voltage Protect Max (near
zero) are not allowed. This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-3).

N/A

+Current
–Current

Current mode only.

Positive and negative output current established by

remote command.
Range (+): 0 to +Current max
Range (–): 0 to –Current min

B.19

+Current max
–Current min

Current mode only.

Maximum (positive) and minimum (maximum

negative) current that can be set.
Value (+): 0 to +I

Onom

Value (–): 0 to –I

Onom

B.21, ,

B.25, B.22