GDS-800 Series Digital Storage Oscilloscope Operation Manual

64

SAVE/RECALL: User can save any waveform in one of two internal memories of the

oscilloscope. These waveforms will be kept even the instrument turned off. The two

saved waveforms also can be applied as the judgment pattern for “Go-No Go”

function. The complete oscilloscope panel setups can be saved in the internal

memory too. There are fifteen saved setup data can be recalled at any time to

perform measurements under the same conditions. The fifteen saved setup data also

can be applied as the item memory for “Program mode”’. Press F1 softkey to select

“setup” save/recall or “waveform” save/recall.

Setup: The oscilloscope can save its complete front panel setups in the nonvolatile

memory (15 set totally).

z

Default Setup: .Recalls the factory default setup.

z

M01~M15: Selects a destination setup memory location to save current setup by

pressing F3 softkey. Press F3 softkey again in order to change the different

memory location.

z

Save: Save current setup into specific memory location.

z

Recall: After specific memory location selected (M01~M15), press the F5

softkey to recall the saved setup.

Waveform: Maximum two sets of waveform can be saved. Use the VARIABLE knob

to adjust the vertical position of saved waveform.

z

Source CH1/CH2/MATH: Press the F2 softkey to select the waveform signal of

channel 1, channel 2 or mathematical waveform to be saved.

z

Trace RefA/RefB: Selects the memory 1 or memory 2 to save the waveform as

reference A or reference B.