beautypg.com

GW Instek GDS-800 Series User Manual User Manual

Page 26

background image

GDS-800 Series Digital Storage Oscilloscope Operation Manual

26

Figure 5-10: Decreasing “delay trigger indicator” shifts the waveform to the right

The sum of left-most “delay trigger indicator” and right-most “delay trigger indicator”

is equal to 10ms (5ms+5ms). Therefore, the above formula is approved.

The maximum “exploring” factor for this oscilloscope is 7 faster “time/div” setting on

the sample rate of original acquired waveform. In the meantime, the “exploring” factor

is only based on the 500 points of memory length.

Users should check the sample rate in advance, and examine Table 5-2 (the row of

memory length=500) to find out the interrelated timebase afterward. After the

interrelated timebase is confirmed, just count 7 faster “time/div” setting from Table 5-

2. The maximum “exploring” factor is appeared. In an easy way, users may just rotate

the horizontal’s TIME/DIV knob directly. The oscilloscope will count automatically.