Orp - setup menu - bar graph o/r 5.13 – Aquametrix SHARK-120/240 Controllers User Manual User Manual
Page 64
ORP - Setup Menu - Bar Graph O/R 5.13
Page 62
S
H
A
R
K
MULTI-PARAMETER CONTROLLER & ANALYZER USER’S MANUAL
ORP - Setup Menu - Bar Graph O/R 5.13
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
UP
DOWN
DOWN
UP
DOWN
DOWN
DOWN
DOWN
UP
DOWN
DOWN
DOWN
UP
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
UP
DOWN
DOWN
DOWN
UP
DOWN
DOWN
Then press the key to store the
selection and return to the Bar Graph
O/R Menu.
Stored
Not stored
UP
NOTE
PRESS THE AND KEYS
TOGETHER TO GO IMMEDIATELY BACK TO
RUN MODE
DOWN
Press the key skip the
setting for the Low Green Led
and move to the setting for the
High Green Led.
With "N" selected, pressing the
key will NOT store the selection, but
simply return to theBar Graph O/R
Menu. This function is useful if you wish
to view the current selection without
making any changes.
Press the key skip the
setting for the HIgh Green Led
and move to store function.
Use the and to
adjust the setting for the High
Green Led.
Press the key to accept
the reading and move to the store
function.
Press the key once
which will move the cursor
back to the RH side.
If you wish to save the setting, press the
key to highlight the Y character
The controller displays the current
setting for the highest green Led of
the bar graph.
Press the key to accept
the reading and move to the High
Green Led setting.
Press the key once
which will move the cursor
over the least sign. digit.
Press the key once
which will move the cursor
back to the RH side.
Use the and to
adjust the setting for the Low
Green Led.
The BAR GRAPH O/R menu allows the user control
over the resolution of the bar graph on the front
panel of the Shark. The factory default for this
function is "OFF" which means the 3 green LEDS
are set to operate between the ON set points of
Relay A and B. This may not always be acceptable,
and this function allows the user to override these
settings.
The controller
displays the
current setting
for the lowest
green led of
the bar graph.
RUN MODE
Press the key
once which will move the
cursor back to the RH
side of the display.
Press the key to adjust the
resolution setting. If OFF was
selected, the menu will move to
the store function directly.
Press the key once
which will move the cursor
over the least sign. digit.
Use the and to select
the override either ON or OFF.
Press the key once
which will move the cursor
over the first character
500mV 25.0C
SETUP
UTILITIES
CALIBRATION
LOW GRN
-199 9 >
STORE? Y N
BAR GRAPH O/R
BAR GRAPH O/R
STORE? Y N
HIGH GRN
1000 >
HIGH GRN
100 0 >
BAR GRAPH O/R
BAR GRAPH O/R
BAR GRAPH O/R
HIGH GRN
1999 >
HIGH GRN
199 9 >
BAR GRAPH O/R
BAR GRAPH O/R
LOW GRN
-100 0 >
LOW GRN
-1000 >
BAR GRAPH O/R
OVERRIDE OFF >
BAR GRAPH O/R
DISPLAY DAMPING
T.DISP OVERRIDE
AUTO RETURN
TEMP SENSOR
PROBE SELECTION
TEMP UNIT
BAR GRAPH O/R
BAR GRAPH O/R
LOW GRN
-1999 >
OVERRIDE ON >
BAR GRAPH O/R
BAR GRAPH O/R
OVERRIDE O FF >
BAR GRAPH O/R
OVERRIDE O N >
BAR GRAPH O/R