Model 2200R ORP analyzer/controller is a de-

pendable industrial grade instrument designed for

controlling rising and falling ORP in the most de-

manding environments.
Extremely easy to operate with a large bright LED

display and intuitive user interface, this micropro-

cessor-based analyzer/controller is packaged in a

NEMA 4X fiberglass reinforced polyester enclo-

sure and used in a wide variety of industrial and

municipal applications.
Frequently used functions are accessed through

an intuitive step-through menu printed directly on

the front panel for ease of navigation. Pressing the

MENU key scrolls through the menu, illuminating a

small LED beside the selected item and displaying

the stored value. Arrow keys are used to change

the value. Seldom used adjustments such as pass-

word activation are set using DIP switches on the

back of the swing-out front panel.

INPUTS

The 2200P accepts two types of ORP probes, the

AquaMetrix P60 Series Differential (three elec-

trode) pH probe and conventional combination

ORP probes.
With an integral pre-amplifier, replaceable salt

bridge cartridge and differential pH measurement

design R60 series differential probes offer a num-

ber of advantages over conventional combination

probes. These advantages include increased dis-

tance from probe to controller (3,000 feet versus 25

feet for a standard combination probe), increased

accuracy, reduced ground-loop interference, and

extended service life.

CALIBRATION

Calibration is fast and easy. Press the MENU key

until the CALIBRATION LED illuminates. Place the

probe in a buffer solution. Use the arrow keys to

set the value. Press ENTER twice. Repeat the pro-

cess for the second buffer solution. The 2200P is
now calibrated.

OUTPUTS

Model 2200R provides three analog outputs, 4-20

mA, 0-5 Vdc and 0-1 mA.
The instrument also provides control of external

devices using two independent control relays.

Factory set for bidirectional control, both control

relays can be field-set to control rising or falling

processes, with easily programmed setpoints for

Relay On and Relay Off.
Each control relay has an independent cycle timer,

with easy to adjust Cycle On and Cycle Off times.

This feature enables a tighter control of batch pro-

cesses by eliminating chemical overshoot.
Control Relay A has a manual override which

places the relay in the AUTO, OFF, or ON mode.

This feature enables the operator to override the

controller from the front panel, turning the relay

on and off. This is a useful feature when servicing

auxiliary devices.
An alarm relay has both high and low setpoints

with a fixed deadband. When any relay is ener-

gized, a corresponding LED on the front panel is

illuminated, clearly indicating alarm conditions and

if auxilliary devices are energized.

DIAGNOSTICS

A self-diagnostics program clearly indicates any

system errors or faults by turning the STATUS LED

on the front panel from green to red. The operator

then scrolls through the menu to STATUS to de-

termine the fault code. The Manual indicates the

source and likely remedy for the fault. When the

status fault is corrected the STATUS LED will turn

back to green.

ENCLOSURE

Model 2200D is packaged in a rugged NEMA 4X

fiberglass reinforced polyester enclosure. It is ide-

ally suited for heavy-duty outdoor applications

such as municipal and industrial wastewater ap-

plications.

Simple step-through menu

design for quick & easy setup

Bidirectional control

through two control relays

with independent setpoints

for Relay On and Relay Off

Cycle-Time option mini-

mizes chemical overshoot

High/low alarm relay

ALARM LED on front panel

Accepts R60 Series differen-

tial ORP probes with replace-

able salt bridge or standard

combination ORP probes

Output signal is field-scal-

able or maximum resolution

Automatic buffer recognition

STATUS errors illumi-

nate LED on front panel

Test feature allows simulation

of ORP readings to test relay

setpoints and analog settings

Password protection and

watchdog timer provide security

Aquametrix Model 2200R

ORP Anayzer / Controller

100 School Street

Andover, MA 01810

978-749-9949

Toll free - 855-747-7623

www.Aquametrix.com

Process Control

Industrial and Municipal Water

Treatment

Industrial and Municipal Waste

Treatment and Neutralization

Fume Scrubbers

Plating, Circuit Board Manu-

facturing, Food and Beverage,

Chemical Processing, Pulp & Pa-

per, Mining, Nuclear Energy and

Pharmaceutical Industries