beautypg.com

Store offset points – Spectra Precision Survey Pro 3.80 Recon GPS Reference Manual User Manual

Page 91

background image

Stakeout Menu

91

Note: When

Store GPS Raw Data

on the Job | Settings | Measure

Mode card (Page R-8) is set to

+ Rx. Raw (

and/or

+OBN

for

Ashtech)

switching from

ROVING

to

OCCUPYING

will start a session in the

receiver, so you will be prompted for a point name and description.
The receiver session will be completed and the measurement stored
when you tap

6WRUH. The occupation is not stored in the Survey Pro

.RAW file if you toggle back to

ROVING.

5HVXOWV / 1(= : displays either the results, or plane coordinates

in the lower corner of the screen.

Station

: is the station at the current rod position.

Offset Dist

: is the perpendicular distance from the line to the rod.

Elev

: is the elevation at the rod position.

Offset

: displays if the rod is on the

Left

or

Right

of the line.

Segment

: displays the type of line segment at the current station.

%DFN: returns to the previous screen.

6WRUH : stores a point for the current rod location.

Store Offset Points

6WDNHRXW 6WRUH 2IIVHW 3RLQWV

The instructions for the Store Offset Points routine for GPS are
similar to the conventional method, except that the

%DFNVLJKW button

is replaced with a

6HWXS +5 button to configure rover antenna and

the backsight information is replaced with rover antenna height
information. See the conventional Reference Manual for details.