11
Post Process Settings
-RE 6HWWLQJV
3RVW 3URFHVV
The Post Process card is used to configure the post processing raw
data storage settings.
Recording Interval
: is where you set the period for
receiver internal raw data recording. Set it to
Off
to
disable post processing data collection in survey pro and
to turn off receiver recording on configuration.
RTK Autonomous Points:
is where you specify action to
take when accepting autonomous points during RTK
data collection.
•
Do not store
: this option will prohibit acceptance
of autonomous points in RTK data collection
routines.
•
Prompt for layer
: this option will prompt the
user whenever an autonomous point is accepted.
The layer specified will be the default layer to
store autonomous points, but the user can over
ride at the prompt.
•
Store on selected layer
: this option will automatically store
autonomous points accepted during RTK data collection
routines on the specified layer.
Layer
: displays the layer selected to store autonomous points.
6HOHFW /D\HU : opens up a layer prompt to allow you to select an
existing layer or create a new layer to store autonomous points.
Session Monitor
: is where you select to use monitoring of post
processing status for the session screen. To have Survey Pro display
warnings during post processing data collection, check
Warn me if
,
and specify threshold values for the number of
SV
,
HDOP
and
memory
.