Base Setup Two – GET and SET
This final Base Setup screen is used to GET an autonomous (here)
position from the receiver and to SET that base position in Survey
Pro and in the receiver. This screen will open when the point is a
new point in the job file, or, in Localization mode when this is the
first geodetic point in the job.
Base Point
: displays the base point name chosen in the
previous screen.
Latitude
: is where you enter the WGS84 latitude for the
base point.
Longitude
: is where you enter the WGS84 longitude for
the base point.
Ellipse
Height
: is where you enter the WGS84 ellipsoid
height for the base point.
Note: You can enter latitude in dd.mmsssss format with
north positive, or you can enter dd mm ss.ssssss N/S.
You can enter longitude in ddd.mmsssssss format with
east positive or you can enter ddd mm ss.sssss E/W.
Average position for epochs before GET
: instructs the receiver to
average autonomous positions for this number of epochs before
returning.
*HW 3RVLWLRQ )URP 5[ : queries the receiver for an autonomous
position. This position can then be used to configure the base by
tapping
6(7.
*36 6WDWXV : opens the GPS Status screen (Page R-20).
Note: It is highly recommended that you do only one autonomous
base setup per job. This will make it much easier to manage the
transformation from geodetic to local plane coordinates in your job. It
is possible, however, to do multiple autonomous setups in a job. If