Spectra Precision Survey Pro 3.80 Recon GPS Reference Manual User Manual
Page 9
Job Menu
9
Note: All receivers need to be in static mode to record Rx. Raw, and
some receivers always record Rx. Raw when in static mode. If the
combination of settings you select is not compatible for your receiver,
you will be prompted to change the settings..
Accept
: is where you control the solution quality acceptable for
storing measurements. You have two options:
•
Fixed RTK only:
Allows storage of fixed solution only.
•
Code, Float, or Fix
: Allows storage of any differential
solution.
Epochs to Average on Accept
: is where you set the number of
epochs to average for the final coordinate. If this number is greater
than one, the final coordinate is calculated using an average of the
number of epochs specified.
Note: This function is not appropriate for every receiver. Some
receivers, when dynamics are set to ‘static’, use Kalman filtering and
other superior techniques to calculate an average position. In this
case, the position returned from the receiver is better with each epoch
and you may actually degrade your result by averaging with Survey
Pro. You should check with your receiver manufacturer for specific
recommendations on field procedure.
Use Acceptance Criteria
: is where you select to apply criteria to
measurement acceptance. When checked, only measurements with
RMS
and/or
PDOP
values below the threshold will be accepted. To
use less than all three criteria, check this box but enter 0.0 for the
criteria you do not wish to apply.
•
H RMS
: is the horizontal RMS threshold for automatic
acceptance or warning on point acceptance.
•
V RMS
: is the vertical RMS threshold for automatic
acceptance or warning on point acceptance.
•
PDOP:
is the PDOP threshold for automatic acceptance or
warning on point acceptance.