R-255
points will be set in the job file, and the projection readjust
mechanism will run to update any job points as required. You must
remember that the solution has not been checked for quality.
Solve Localization
Before the Solve Localization wizard starts, the localization
is computed using all the control points, and then the
automatic blunder detection routine runs to detect low
quality control points. Tapping Yes at this prompt will
automatically disable the horizontal and/or vertical control
that results in a poor solution. This can be overridden in
the next screen.
The Solve Localization wizard is used to solve a horizontal and
vertical adjustment for a coordinate system. The user interface and
procedure to solve a localization in Ground – TDS Localization mode
and Mapping Plane mode are very similar.
Solve Localization – Residuals
The Solve Localization Residuals screen is used
to display the residuals from the least squares
solution, and to change your control point
selections and re-solve the adjustment if
desired.
If Yes is displayed in the H or V column, it
indicates the corresponding control point will
be included in the horizontal or vertical
localization solution, respectively. These can
be toggled between Yes (included) or blank (not
included) by tapping them. If the blunder
detector detected any poor quality control, it
will automatically turn off that control before this screen opens.
The possible outcomes of the solve localization and blunder detection
are:
• Green Light: If the localization solved and no blunders were
detected, you will see a green light and the status line will