beautypg.com

Check control point screen – Spectra Precision Survey Pro v4.6 Ranger Reference Manual User Manual

Page 209

background image

Survey Menu – GPS Module

R-201

Control : opens the Occupy Control Point screen, where geodetic

coordinates are measured at a point with local coordinates and added

to that point record in the job file.

Check Control Point Screen

Survey Control Points

Check Point

.

or Data Collection Control Check Point

.

The Check Control Point screen is used to check a control point when

you want to verify the quality of the coordinate system solution.

Coordinates

: displays the local coordinates

computed using the current measurement and

the latest projection solution.

Solution

Quality: displays the quality of the

current measurement: the solution type, the

number of satellites used, and the horizontal

and vertical precision computed by the
receiver. These values are explained with the

GPS Status screen (Page - R176)

Errors

: displays the differences between the

computed local coordinates and the known

coordinates for the control point.

Note: If the Errors are larger than the measurement precision of the
instrument, you probably have a problem with your projection
solution.

Session Time

: displays the total occupation time so far for this

measurement.

Count Status

: displays Measuring when you have current coordinates

from the receiver and the screen is updating with the latest

measurement. If you are using Epoch Averaging, Averaging is
displayed after you tap Accept while the number of epochs is
averaged in Survey Pro. Suspended is displayed if you are not
receiving valid data from the receiver.

GPS Status : opens the GPS Status screen (Page R-176).