beautypg.com

Post process settings – Spectra Precision Survey Pro v4.6 Ranger Reference Manual User Manual

Page 119

background image

Job Menu – GPS Module

R-111

the number of epochs specified to calculate the final position using a
simple (non-weighted) average.

Note: This function is not appropriate for every receiver. Some

receivers, when dynamics are set to ‘static’, use Kalman filtering and
other superior techniques to calculate an average position. In this

case, the position returned from the receiver is better with each epoch
and you may actually degrade your result by averaging with Survey

Pro. You should check with your receiver manufacturer for specific
recommendations on field procedure.

Post Process Settings

Job Settings Post Process or

Connect to Receiver Receiver Settings

The Post Process card is used to configure the settings for logging

post processing data, and the collecting and storing of post processing

points in Survey Pro.

RTK Autonomous Points:

is where you specify

action to take when accepting autonomous

points during RTK data collection. There are
three options.

Do not store: this option will prohibit

acceptance of autonomous points in

RTK data collection routines.

Prompt for layer: this option will

prompt the user whenever an

autonomous point is accepted. The
layer specified will be the default layer

to store autonomous points, but the user can over ride at the

prompt.

Store on selected layer: this option will automatically store

autonomous points accepted during RTK data collection
routines on the specified layer.