Code 43: setting of high-resolution mode [ *s_cyc – Yokogawa GD40 Gas Density Detector User Manual
Page 119
![background image](/manuals/360159/119/background.png)
<6. CALORIE / PARAMETER SETTING>
6-30
IM 11T3E1-01E
CODE 42: Indication of Software Version [*REV] (Read-only)
This setting allows the software version to be confirmed (indicated).
Indicated as X.XX
42
*CODE
*SERVC
X.XX
*REV
[ENT]
[ENT]
[YES]
F0626.ai
*
1
*
2
*
3
*1: See "Figure 6.4 Process at the Setting Level" on page 6-12.
*2: Enter the code number.
*3: Pressing the [ENT] key returns to the service level with the indication [*SERVC].
This parameter does not accept the [ ] and [ ] key input.
Figure 6.26 Indication of Software Version
CODE 43: Setting of High-resolution Mode [*S_CYC]
This setting selects between the normal mode and the high-resolution mode.
・ Normal mode:
0
・ High-resolution mode: 1
43
*CODE
*SERVC
X
*S_CYC
[ENT]
[ENT]
[YES]
F0627.ai
*
1
*
2
*
3
*1: See "Figure 6.4 Process at the Setting Level" on page 6-12.
*2: Enter the code number.
*3: Set a value by using the [ ], [ ] and [ENT] keys.
Figure 6.27 Setting of High-resolution Mode