Chapter 8: Programming Page

8

The Programming Page allows you to select what parameters appear on the Operations Page. To go to the Pro-
gramming Page, press both the Advance ‰ and Infinity ˆ keys for six seconds from the Home Page. [Prog] will
appear in the upper display and

[PAgE] will appear in the lower display.

• Press the Advance Key ‰ to move through the parameter prompts.

• Press the Up ¿ or Down ¯ key to change the parameter value.

• Press the Infinity Key ˆ at any time to return to the Home Page display.

Note: This chapter only applies to the static set point and profiling versions of the Series SD (SD_C or R - _ _ _ _ - _ _ _ _).

Display

Parameter name

Description

Settings

Range

(Integer values for Modbus

in parentheses.)

Default

Modbus*

(less 40,001

offset)

Read/Write

Appears if"

[``P1]

Parameter Location 1

[none]

(0) None

[`CAL]

(1) Calibration Offset

[`C-F]

(2) Temperature Units (Setup

Page)

[A1;Lo]

(3) Alarm 1 Low

[A1;hi;]

(4) Alarm 1 High

[A2;Lo]

(5) Alarm 2 Low

[A2;hi]

(6) Alarm 2 High

[A3;Lo]

(7) Alarm 3 Low

[A3;hi]

(8) Alarm 3 High

[hys1]

(9) Alarm Hysteresis 1 (Setup

Page)

[hys2]

(10) Alarm Hysteresis 2 (Setup

Page)

[hyS3]

(11) Alarm Hysteresis 3 (Setup

Page)

[addr]

(12) Modbus Device Address

(Setup Page)

[`Aut]

(13) Autotune

[A-m]

(14) Auto-Manual

[Po;ht]

(15) Power Heat

[Po;CL]

(16) Power Cool

[ht;M]

(17) Heat Control Method

[Pb;ht]

(18) Prop. Band Heat

[It;ht]

(19) Integral Heat or

[re;ht]

(19) Reset Heat

[dEht]

(20) Derivative Heat or

[ra;ht]

(20) Rate Heat

[db;ht]

(21) Dead Band Heat

[h;hys]

(22) Heat Hysteresis

[CL;M]

(23) Cool Control Method

[Pb;Cl]

(24) Prop. Band Cool

[It;Cl]

(25) Integral Cool or

[rE;Cl]

(25) Reset Cool

[dE;Cl]

(26) Derivative Cool or

[ra;Cl]

(26) Rate Cool

[db;Cl]

(27) Dead Band Cool

[C;hys]

(28) Cool Hysteresis

[prop]

(29) Proportional Term

[``It]

(30) Integral Term

[``dE]

(31) Derivative Term

[rP;rt]

(32) Ramp Rate (Setup Page)**

[Po;ht] (15) 48 R/W

All parameter loca-
tions always appear
on the Programming
Page.

Static set point ver-

sion

(SD_C - _ _ _ _ - _ _

_ _ ) P1 to P20

Profiling version

only.

(SD_R - _ _ _ _ - _ _

_ _ ) P1 to P23

[~~P2]

Parameter Location 2

[`gsd] (35) 49 R/W

[~~P3]

Parameter Location 3

[`Aut] (13) 50 R/W

[~~P4]

Parameter Location 4

[`CAL] (1)

51 R/W

[~~P5]

Parameter Location 5

[ht;m] (17) 52 R/W

[~~P6]

Parameter Location 6

[pb;ht] (18) 53 R/W

[~~P7]

Parameter Location 7

[re;ht] (19) 54 R/W

[``P8]

Parameter Location 8

[ra;ht] (20) 55 R/W

[``P9]

Parameter Location 9

[h;hys] (22) 56 R/W

[`P10]

Parameter Location 10

[CL;m] (23) 57 R/W

[`P11]

Parameter Location 11

[pb;Cl] (24) 58 R/W

[`P12]

Parameter Location 12

[re;CL] (25) 59 R/W

[`P13]

Parameter Location 13

[ra;Cl] (26) 60 R/W

[`P14]

Parameter Location 14

[C;hys] (28) 61 R/W

[`P15]

Parameter Location 15

[A1;hi] (4)

62 R/W

[`P16]

Parameter Location 16

[A1;Lo] (3)

63 R/W

[`P17]

Parameter Location 17

[A2;hi] (6)

64 R/W

[`P18]

Parameter Location 18

[A2;Lo] (5)

65 R/W

[`P19]

Parameter Location 19

[A3;hi] (8)

66 R/W

[`P20]

Parameter Location 20

[A3Lo] (7)

67 R/W

[`P21]

Parameter Location
21***

[Ent1] (32) 68 R/W

[`P22]

Parameter Location
22***

[Ent2] (33) 69 R/W

[`P23]

Parameter Location
23***

[Ent3] (34) 47 R/W

Note: All parameter locations have the same range of possible values.

**Static set point version (SD_ C - _ _ _ _ - _ _ _ _ )

***Profiling version only. (SD_ R - _ _ _ _ - _ _ _ _ )