Instruction 9- positive pulse contact – Maple Systems MAPware-7000 User Manual
Page 30
MAPware-7000 Ladder Logic Guide
22
1010-1041 rev. 00
Instruction 9- Positive Pulse Contact
Expression:
Space Requirement: 1 line x 1 column Location Requirement: Left rail, Middle
Function:
When the input is ON and the device A is changed from OFF to ON (OFF at last scan and ON at
this scan), the output is turned ON.
This instruction is used to detect the device changing from OFF to ON.
Execution Condition:
Input
Operation
Output
OFF
Regardless of the state of device A.
OFF
State of device A is OFF.
OFF
ON
State of device A is ON.
A is OFF at last scan.
ON
A is ON at last scan.
OFF
Operand:
Coil or Bit
Register
Constant
Index
Name
X
Y
B
S
T.
C.
M
X
W
Y
W
B
W
S
W
T C
D
I
J
K
M
W
A
Device
√
√
√
√
√
√
Example:
Timing Diagram:
B0100 comes ON for only 1 scan when X0000 is ON and X0003 changes to ON
.