4. SCON-CA
90
(6) Status LED indications
The board operating condition and network condition can be checked using the two LEDs provided on the front
side of the controller.
LED Color
Indicator
condition
Description of indication (Meaning of indication)
Lit
The board is online with the fieldbus network and communicating
normally.
Green
Blinking
The board is offline from the fieldbus network.
STATUS1
Orange
Blinking
A communication error is present.
Lit
The board is operating properly.
Green
Blinking
The board is not yet ready.
STATUS0
Orange Lit
A communication hardware error was detected when the board
was not yet ready.
(Note 1) After the necessary parameters have been set, reconnect the controller power and return the mode
selector switch on the front side of the controller to the AUTO position. If the switch remains in the
MANU position, PLC operation cannot be performed.
(Note 2) The baud rate is automatically set according to the corresponding setting on the master side and
thus need not be set.