5. Flow and Commands of Basic MECHA

TROLINK Communication


196


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)

Signal type

Bit

Symbol

Description

Details

Current position

32 bit data

-

32-bit signed integer indicating the current position.
The unit is 0.01 mm.
(Example) Reading: 000003FF

H

= 1023 (decimal) = 10.23 mm

* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

5.6 (3)

Command current 32-bit data

-

32-bit integer.
The value of electrical current specified by the present
command is indicated.
The unit is mA.
(Example) Reading: 000003FF

H

= 1023 (decimal) = 1023 mA

5.6 (3)

Current speed

32-bit data

-

32-bit signed integer.
The current speed is indicated.
Positive value: The actuator is moving in the direction opposite
home.
Negative value: The actuator is moving in the direction of home.
The unit is 0.01 mm/sec.
(Example) Reading: 000003FF

H

= 1023 (decimal) = 10.23

mm/sec
* If this data is read as a hexadecimal value, a negative value

is indicated by a 2’s complement.

5.6 (3)

Alarm code

16-bit data

-

16-bit integer.
If an alarm occurs, an alarm code will be output.
0 is output when no alarm is present.
For details on alarms, refer to the operation manual for the
controller.

5.6 (3)

Force feedback

data

32-bit data

-

32-bit signed integer.

The current load cell reading is indicated.
The unit is 0.01 N.

* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

5.9 (3)

Total moving

count

32-bit data

-

32-bit integer.
The unit is times.

-

Total moving

distance

32-bit data

-

32-bit integer.
The unit is m.

-

b15 -
b14 -
b13 -
b12 -
b11 -
b10 -

b9 -
b8 -
b7 -
b6 -
b5 -
b4 -
b3 -

Cannot be used.

-

b2 CEND

Load cell calibration is complete: This signal turns ON
when calibration is complete.

5.4.11

(32)

PLC in

put

Status signal 1

b1 BALM

Absolute battery voltage low warning: This signal turns
ON when the voltage drops.

5.4.11

(28)