IAI America PCON-CFA User Manual
Page 180
5. Flow and Commands of Basic MECHA
TROLINK Communication
174
Setting of parameter No. 25
Force control mode 1
Force control mode 2
6 7
Category Port
No. Symbol
Signal
name Symbol
Signal
name
0 PC1
ST0
Start
position
0
1 PC2
ST1
Start
position
1
2 PC4
ST2
Start
position
2
3 PC8
ST3
Start
position
3
4 PC16
Command position number
ST4 Start
position
4
5 -
-
6 -
-
7 -
Cannot be used.
-
Cannot be used.
8 CLBR
Load cell calibration
command
CLBR -
Load cell calibration
command
9
BKRL
Forced brake release
BKRL
Forced brake release
10
RMOD
Operation mode
RMOD
Operation mode
11
HOME
Home return
HOME
Home return
12 *STP
Pause
*STP
Pause
13 CSTR
Positioning
start
-
14 RES
Reset
RES
Reset
PLC
output
o
SCON-C
A input
15
SON
Servo ON command
SON
Servo ON command
0 PM1
PE0
Completed position number
0
1 PM2
PE1
Completed position number
1
2 PM4
PE2
Completed position number
2
3 PM8
PE3
Completed position number
3
4 PM16
Completed position number
PE4
Completed position number
4
5
TRQS
Torque level status
TRQS
Torque level status
6 LOAD
Load output judgment
status
LOAD
Load output judgment status
7 CEND
Load cell calibration
complete
CEND
Load cell calibration
complete
8
PZONE/
ZONE1
Position zone/
Zone 1
PZONE/
ZONE1
Position zone/
Zone 1
9
RMDS
Operation mode
RMDS
Operation mode
10
HEND
Home return complete
HEND
Home return complete
11
PEND
Positioning complete signal
PEND
Positioning complete signal
12
SV
Operation ready
SV
Operation ready
13
*EMGS
Emergency stop
*EMGS
Emergency stop
14 *ALM
Alarm
*ALM
Alarm
SCON-C
A output
o PLC
input
15
*BALM
Battery alarm
*BALM
Battery alarm
* Indicates a signal that is normally ON.
The signals denoted by “Cannot be used” are not controlled. (ON/OFF statuses of these signals are
indeterminable.)