5 i/o signal timings – IAI America PCON-CFA User Manual

Page 74

background image

3. SCON-CA/CF

A


68

3.5 I/O

Signal

Timings


The maximum response time after a given control signal is turned ON to operate the ROBO Cylinder using the
PLC’s sequence program, until a response (status) signal is turned, is expressed by the formula below:

Maximum response time (msec) = Yt + Xt + 2 + Command processing time (operation time, etc.)

Yt: Master station

o slave station transmission delay time

Xt: Slave station

o master station delay time



For the master station

o slave station transmission delay time (Yt) and slave station o master station delay time

(Xt), refer to the operation manuals for the PROFIBUS-DP master unit and the PLC in which the master unit is
installed.






























Field network transmission delay time

Command

processing time

PLC sequence program

Control signal

Status signal

ACON, PCON

Control signal

Status signal

Master station

o slave

station transmission
delay time (Yt)

Slave station

o master

station delay time (Xt)