IAI America RCS2-SD5N User Manual
Page 49

6. Installation
-43-
6.2.3 Installation of Flange
Provide a flange-shaped sheet and install the actuator onto this sheet from the back.
x
Use the tapped hole on the actuator to install the actuator onto the flange using the M5 countersunk screw.
x
Secure the flange with the actuator mounting plate using screws.
If positioning is required, insert positioning pins.
Installation of actuator and flange
Tightening torque
Type
Tapped hole size
Plate is made of steel
material
Plate is made of
aluminum material
RP5N
M5, depth 10
7.28 Nxm
3.42 Nxm
(Reference drawing of flange)
4-5.5 through
(M5)
2-reamed hole
4-5.5 through
Countersunk, for countersunk screw
Actuator mounting
hole
Actuator mounting plate
Positioning pin hole (2 locations)
Positioning pin hole (2 locations)
Flange
Positioning pin (2 pcs)