IAI America RCS2-SD5N User Manual
Page 30
6. Installation
-24-
6.1.2 Installation of Detent
The short types (nut affixing types) have no detent on the rod.
If you are using the RN5N without guide, install a detent, if necessary, by referring to the figure below.
Caution: If you hear any abnormal noise from the actuator or find the grease on the screw darker within
several weeks after the start of operation, the concentricity or parallelism between the actuator
mounting hole in the actuator mounting plate and end-bracket mounting hole in the guide-side
bracket may not be appropriate. Make sure the concentricity is within 0.05 mm and parallelism,
within 0.02 mm. Wipe off darkened grease and apply new grease.
[Refer to 10.6, “Greasing.”]
End-bracket mounting hole
Detent
Actuator mounting hole
Actuator mounting plate