background image

6. Installation

-24-

6.1.2 Installation of Detent

The short types (nut affixing types) have no detent on the rod.

If you are using the RN5N without guide, install a detent, if necessary, by referring to the figure below.

Caution: If you hear any abnormal noise from the actuator or find the grease on the screw darker within

several weeks after the start of operation, the concentricity or parallelism between the actuator

mounting hole in the actuator mounting plate and end-bracket mounting hole in the guide-side

bracket may not be appropriate. Make sure the concentricity is within 0.05 mm and parallelism,

within 0.02 mm. Wipe off darkened grease and apply new grease.

[Refer to 10.6, “Greasing.”]

End-bracket mounting hole

Detent

Actuator mounting hole

Actuator mounting plate