IAI America RCS2-SD5N User Manual
Page 38

6. Installation
-32-
4-5.5 through
2-reamed hole
35H8
6.1.3 Installation of Flange
Provide a flange-shaped sheet and install the actuator onto this sheet from the back.
x
Use the nut on the actuator rod to install the actuator onto the flange.
x
Secure the flange with the actuator mounting plate using screws.
If positioning is required, insert positioning pins.
(Note) For the actuator mounting hole in the actuator mounting plate, provide a hole larger than the
dimension of the nut so as to provide a clearance for the nut.
Type
Nut diameter
RN5N
48.6
Installation of actuator and flange
Type
M
Width across flats
Maximum tightening torque
RN5N
M35 x 1.5
46
50 Nxm
(Reference drawing of flange)
Actuator mounting hole
Actuator mounting plate
Positioning pin hole (2 locations)
Positioning pin hole (2 locations)
Flange
Positioning pin (2 pcs)