6. Installation
-36-
End bracket
Guide-side bracket
Flat washer
M8 nut
End bracket
Guide-side bracket
Flat washer
M8 nut
[How to install the detent, and points to note]
[1] Keep the concentricity between the actuator mounting hole in the actuator mounting hole and end-bracket
mounting hole in the guide-side bracket, to within 0.05 mm. Also keep the parallelism to within 0.02 mm.
Type
Lead
Guide-side bracket
L
Without counterbore
26.7r0.1
2.5
With counterbore
25.2r0.1
Without counterbore
27.0r0.1
RP5N
5.10
With counterbore
25.5r0.1
Tightening torque for end clasp
Type
Tightening torque
RP5N
7 Nxm
Caution: Do not join the actuator detent using a floating joint.
A radial load will be applied due to an eccentricity of the screw shaft, resulting in actuator
malfunction or premature damage.
RP5 Guide-side bracket(without counterbore)
RP5 Guide-side bracket(with counterbore)
Actuator mounting plate
Guide-side bracket
Detent guide
(prepared by the customer)
(prepared by the customer)
End bracket
13 mm across
flats