beautypg.com

6 connecting to physical alarm modules – Ronan X11CA Software Manual User Manual

Page 48

background image

Rev 1.3 Series X11CA Computer Annunciators: X11CA Configuration Software User’s Manual

4. X11CA Software Operation

Hardware Control-© 2003 Ronan Engineering

44

E

E

x

x

a

a

m

m

p

p

l

l

e

e

:

:

F

F

i

i

g

g

u

u

r

r

e

e

4

4

-

-

1

1

(

(

M

M

o

o

d

d

u

u

l

l

e

e

1

1

:

:

3

3

c

c

h

h

a

a

n

n

n

n

e

e

l

l

s

s

,

,

M

M

o

o

d

d

u

u

l

l

e

e

2

2

:

:

4

4

c

c

h

h

a

a

n

n

n

n

e

e

l

l

s

s

)

)

X

X

1

1

1

1

C

C

A

A

-

-

I

I

M

M

S

S

w

w

i

i

t

t

c

c

h

h

:

:

P

P

R

R

G

G

M

M

Click on the System menu and then the PrintReport submenu.

Verify that the information is correct and there is no error messages.

X11CA SYSTEM REPORT.


File Access Info:

C:\ \SAMPLE-CONFIG.CFG
Created: 1/31/03 1:16:50 PM
Last Accessed: 1/31/03 1:16:50 PM
Last Modified: 1/20/03 10:15:11 AM


WIDHT : 2
HIGH : 1


GLOBAL SYSTEM PROPERTIES
TEST TYPE : OPERATIONAL TEST
HORN1 TYPE : Continuous
HORN2 TYPE : Continuous

CTA FOLLOW : FC,NNE
SERIAL DATA FOLLOW : FC

ALARM MODULES PROPERTIES

----------------------------------------------------------------------------------------------
|Module|Channel|Seq. |Input|FC Time|Ser. Output|AUX Rel | TO |HORN| GF1 | GF2 |Global
|Number|Number |Type |Type |Delay,s|Data Follow|Follow |Follow | |Inhibit|Inhibit|Prop.
----------------------------------------------------------------------------------------------
| 1 | 1 |A-1 | FC | 0.02 | FC |FC, NNE |FC, NNE| H1 | | | OK |
| | 2 |A-1 | FC | 0.02 | FC |FC, NNE |FC, NNE| H1 | | | OK |
| | 3 |A-1 | FC | 0.02 | FC |FC, NNE |FC, NNE| H1 | | | OK |
----------------------------------------------------------------------------------------------

| 2 | 1 |F3M-1| FC | 0.02 | FC |ACK, NNE|FC, NNE| H1 | | | OK |
| | 2 |F3M-1| FC | 0.02 | FC |ACK, NNE|FC, NNE| H1 | | | OK |
| | 3 |F3M-1| FC | 0.02 | FC |ACK, NNE|FC, NNE| H1 | | | OK |
| | 4 |F3M-1| FC | 0.02 | FC |ACK, NNE|FC, NNE| H1 | | | OK |
----------------------------------------------------------------------------------------------

*- The alarm module needs to be reprogrammed

x11CA – C:\sample-config.cfg page 1

1/31/03 2:11:34 PM

Figure 4-32 Example Report

4.6 Connecting to Physical Alarm Modules

Before making connection from the Configuration Software to physical alarm
modules, make sure that power to the X11CA-IM device is on and its switch 8
(SW8) is set to PRGM side.

When the X11CA-IM device is in the program mode, the red ERROR LED on the
X11CA-IM device keeps blinking because the Configuration Software bypasses the