Probe insertion length (from process end of mounting thread to probe sensing tip. 

3.1.3 SERIES 9060H PROBES SPECIFICATIONS 

MODEL  

9060H

9060UL/UH

Application  

Combustion flue 

Combustion flue gases  

 

gases below  

above 700°C (1290°F) with 

 

900°C (1650°F) 

no contaminants.  

 

Refer to note 1 

eg. natural gas, light oils 

Temperature Range  

0 to 900°C. Refer to note 2 
(32 to 1650°F) 

700 to 1400°C  
(1470 to 2550°F) 

Length  

250 to 2000 mm 

500 to 1500 mm  

 

(10” to 80”)  

(20” to 60”)  

Process Connection 

1 ½ BSP " or NPT

¾ BSP " or NPT 

Electrical  Connection 

Weatherproof  plug‐in  connector  or  optional  screw  terminals.    The  plug 
connector can be supplied with the cable.  

Cable  

Order a specific length with the transmitter 

Heater  

Yes  

No 

Thermocouple  

K, integral  

R, integral 

Response Time  

Typically < 4 secs. 

Typically < 1 sec  

Head Temperature  

‐25 to 100°C (‐15 to 210°F) with weatherproof connector  

 

‐25 to 150°C (‐15 to 300°F) with screw terminals 

Reference Gas  

Ambient  air,  50  to  150  cc/min  (3  to  9  scim).  Pump  can  be  supplied  with 
transmitter.  

Ref Air Connection  

1/4 NPT " 

Integral  air  line  in  probe  cable. 
Barbed fitting to 3/16" ID PVC tube. 

Filter  

Removable  sintered  titanium  alloy  particulate  filter,  30  micron  standard, 
optional 15 micron available. Refer to note 2  

Calibration Check Gas 
Connection  

1/8 NPT female "

1/8 NPT female " 

Weight  

2 kg (4.4 lb) plus
165 g (5.8 oz) / 100 mm 
(4”) length   

1 kg (2.2 lb) plus 
100 g (3.5 oz) / 100 mm 
(4”) length  

Notes:  1.  Care  must  be  taken  to  avoid  contact  with  explosive  or  inflammable  gases  with  9060H
heated  probes  when  hot.  Teledyne  Analytical  Instruments  transmitters  have  built  in  safety 
protection.  
2. Process gas temperature must be below 800°C if the filters are fitted.

 

Please contact factory for corrosives other than sulfur or zinc. We can provide test materials to try 
in your atmosphere.