background image

7-4

D0536 Rev. B

StrongArmPark DC: Programming & Operations Manual

www.hysecurity.com

s

trong

a

rm

p

ark

dC C

enter

l

oop

C

onfIguratIon

Two different types of vehicle loop connections are shown in the illustration:

• HY-5A - HySecurity vehicle detector (see “Connecting HY-5A Vehicle Detectors” on page 4-13 for more

information).

• Generic box detector

COM

COM

COM

COM

COM

COM

COM
COM

STOP
OPEN

RADIO

CLOSE

OPEN

OPEN

PARTIAL

EYE

OPEN

EYE

CLOSE

EXIT

LOOP
BLOCK

EXIT

IN OBS

LOOP

OUT OBS

LOOP

CENTER

LOOP
EDGE
EYE

COM
+ 24 V
EMERG

OPEN

SHOW

LEDs

RADIO OPTIONS

EDGE +24V OPE

N COM

DUAL GATE

COM

B

A

U

SE

R2

COM NO

DC

COMMON

TERMINALS

HY-5A

FREE EXIT

HY-5A

INSIDE LOOP

(Inner Arming

Loop)

HY-5A

OUTSIDE LOOP

(Outer Arming

Loop)

HY-5A

CENTER LOOP

RS-485

COMMUNICATION

USB PORT

USER RELAY 1

Electro-mechanical

USER RELAY 2

Solid state

24VDC

24VDC

24VAC

24VAC

12VDC

12VDC

VEHICLE LOOP

HY-5A

Access controls

Radio receiver

Connection for Dual (Master/Second or Sally Port)

or Sequenced gate systems.

(Ex. Card reader, keypad)

Red LED

heart

beat

indicates

processor is

working.

Multi-colored LED

indicates power and gate

status.

RS-232

Press button to light

active inputs.

Ethernet

expansion

VEHICLE LOOP

Loop Detector

Common

To LOOP terminal on Smart DC Controller

Box Detector

If you have a simple set up, similar to the single center loop diagram on page

7-3, you can change the default from re-opening if the center loop is triggered

to only pause when triggered. Closure continues as soon as the loop is clear

again. See the “CR” menu item in the “Installer Menu: Table 2.” on page 3-7.

CR 0 REVERSE

CENTER LOOP

OPEN

CLOSE

STOP

MENU