Etting – Controlled Products Systems Group STRONGARMPARK DC 10 User Manual
Page 37

www.hysecurity.com
Display Menu
D0536 Rev. B
3-11
s
ettIng
tHe
t
Ime
and
d
ate
A feature of the Smart DC Controller is its 24-hour, 365 day clock. Make sure it is set to the appropriate time
zone. An accurate time and date allows the diagnostic log to date stamp operational data which indicates when
Alerts, Faults and Errors occur. The log helps in troubleshooting and can be viewed using the S.T.A.R.T. software
application via a laptop connected to the USB or RS-232 port. For more information, refer to “Smart Touch
Analyze and Retrieve Tool (S.T.A.R.T.)” on page 6-1.
To set or adjust the time or date, take the following steps:
1. At a gate status display, press the MENU button twice. This
accesses the User Menu and the CLOSE TIMER display ap-
pears.
2. Press NEXT or PREV until the SET CLOCK display appears.
3. Press SELECT.
4. CL blinks.
5. Press NEXT or PREV to change the number to 1.
6. Press SELECT to accept the display.
7. The date and time display appears. Use the SELECT and
NEXT buttons in the same manner as before to adjust the
date and time.
NOTE: A date or time field must be blinking before it
can be changed.
8. To accept what appears on the date and time display, press
SELECT.
9. To exit the User Menu, press the MENU button. A gate status
appears in the display indicating you have returned to Run
Mode.
NOTE: A lithium coin battery supports the clock so the date and
time is retained even when the main power is turned off. Replace
the battery about every five years with a DL 2025, DL 2032 or
CR 2025 or CR 2032 battery. Refer to Clock Battery Replacement.
CL 1
SET CLOCK
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
01/05/13 00:00
^^
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT