3-6

D0536 Rev. B

StrongArmPark DC: Programming & Operations Manual

www.hysecurity.com

User Menu

Setting Options

Menu Tasks & Explanations

SDC Wire

Connections

DS 0 (OFF)

Diagnostic Logs

0 = off
1 = detailed

Set to 0, the SDC logs pertinent operator events
such as faults, errors, or menu manipulation. When
experiencing intermittent problems, set this item to
1 to record all operator open and close events, in
addition to the normal alert, fault and error logs. This
parameter automatically resets to the default 0 (off)
after 24 hours.

USB or RS-232 cable
and laptop computer
loaded with HySecurity
free S.T.A.R.T. software is
required to read the log
file.
Visit www.hysecurity.com

PD 0 

Set Password

0 = Off
1 = On, Set Password

To enter a password (up to 80 characters) for
network connectivity, select 1. You can use the menu
navigation buttons to enter the password (SELECT,
NEXT, SELECT). When the password is set, the
display returns to the 0 setting.
NOTE: A System Address (SA) value in the Installer
Menu must be set before the Set Password display
can appear in the User Menu.

Network: Ethernet or
RS-485


I

nstaller

m

enu

The Installer Menu options provide more advanced configurations for

the gate operators. Access to the Installer Menu is through the User

Menu. The navigational buttons are the same in both menu modes.

Access:

While a static Run Mode code is being displayed, press the MENU

button twice. (Bypasses the operator status displays.)

When the Close Timer display appears:

1. Access the Installer Menu by simultaneously pressing and hold-

ing the RESET and OPEN buttons.

2. Release both buttons and the Learn Limit display appears. The

LL display is the first item in the Installer Menu.

NOTE: Installer Menu options can also be configured through the use of a lap-
top computer and the S.T.A.R.T. software.

Table 2 describes the Installer Menu items and supplies the factory defaults. (Factory settings shown in bold.)

CT 0 (OFF)

CLOSE TIMER

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

LL 0 (OFF)

LEARN LIMIT

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT