Dc c, Sdc t, Mart – Controlled Products Systems Group STRONGARMPARK DC 10 User Manual
Page 44: Ontroller, Nputs, Erminal

4-4
D0536 Rev. B
StrongArmPark DC: Programming & Operations Manual
www.hysecurity.com
s
mart
dC C
ontroller
I
nputs
When using AC power, an LED lights next to active inputs. On a new operator, no active input should appear until
external accessories and wiring are attached. If any inputs are active before connecting external wiring, refer to
“Troubleshooting” on page 5-1.
1. Test the open and close function of the barrier arm before wiring to accessory devices (external control
inputs).
NOTE: If you are using the operator strictly in a DC capacity, the Smart DC Controller has a tact button you can
push which lights an LED next to the active inputs. This button is in the bottom left corner of the SDC board. Press
the SHOW LEDs push button to verify the status of the terminal inputs.
2. All control device inputs listed below are shown as a single input. In most cases, the second wire is
connected to one of the eight Common Terminal Bus (COM) on the Smart DC Controller board.
NOTE: The Emergency Close and Fire Dept. Open inputs are an exception and require a +24V input, as well as
activation in the Installer Menu. For convenience, a +24V is located next to the EMERG OPEN terminal.
sdC t
ermInal
I
nputs
NOTICE: A label on the Control Box indicates the change in inputs for revenue control sites. Refer to “Revenue Control
Parking Applications” on page 4-10.
SDC Inputs Chart
Label
SDC Terminal
Wire Connections
Commonly used for...
COM
COM
Common terminal. all user inputs are
energized when connected to common
except Emergency Open.
All inputs except Emergency
Open.
STOP
Stop* Button
Normally Closed input. Jumper to Com-
mon if input is not being used.
Line of sight, external stop button
or 3-button station.
OPEN
Open* Button
Normally Open (N.O.) input. Do not use
for radio or remote access controls.
Line of sight, external open but-
ton or 3-button station.
CLOSE
Close Button
N.O. input. Do not use for radio or
remote access controls.
Line of sight, external close but-
ton or 3-button station.
RADIO
OPEN
Remote Open &
Radio Control
N.O. input. For radio/remote open
device: Access the RO from the User
Menu and set to 1 for close function too.
Remote access control or radio
controls
OPEN
PARTIAL
Open Partial
Normally Open (N.O.) input.
Supervised access controls