beautypg.com

Secure public, Dc c, Trong – Controlled Products Systems Group STRONGARMPARK DC 10 User Manual

Page 75: Enter, Ayout

background image

www.hysecurity.com

Reference

D0536 Rev. B

7-3

s

trong

a

rm

p

ark

dC C

enter

l

oop

l

aYout

SECURE

PUBLIC

Uni- or Bi-directional Traffic Control

Vehicles must pass from one loop

to the next without loss of detection

Dimension “A” = 6 ft minimum to 10 feet

maximum (305 cm).

Dimension “B” = 2 ft min. to 4 feet max.

(61 to 122 cm) between loop and edge

of roadway, is recommended.

Dimension “C” = 4 ft min to 8 ft max

(122 to 244 cm). Vehicles must pass

from one loop to the next without

loss of detection.

Dimension “D” = 2.5 ft (76 cm) to help

mitigate tailgating, but may not detect

higher bed vehicles.

Dim D = 6 feet (183 cm) to detect higher

bed vehicles.

Dimension “E” = 10 to 12 feet (305 to

366 cm) if an access control device

is employed.

Dimension “F” = 2 foot minimum

clearance (61 cm).

CENTER

LOOP

INNER

ARMING

LOOP

(IALD)

OUTER

ARMING

LOOP

(OALD)

FREE EXIT

LOOP

(optional)

A

B

C

C

E

Optional access control

devices (card reader, etc.)

Align along 6 ft edge of the

Outer Arming Loop.

F

x

H

Inductance Field created

when Loop is active.

Effective height of loop (H)

is 2/3 the distance of X.
To detect higher bed vehicles,

keep the short side at 6 ft (183 cm)

which creates a 4 ft (122 cm)

inductance field above ground.
If tailgating is a concern, a

smaller loop is needed, but it

may not detect high bed vehicles.

Vehicle Loop: Active

F

D

PEDESTRIAN GA

TE & WALKWA

Y

This manual is related to the following products: