General Maintenance

D0536 Rev. B

6-3

m

eCHanICal

m

aIntenanCe

CAUTION

Before checking the internal mechanisms of the operator, turn off all power switches.

The StrongArmPark DC mechanical maintenance is not in depth or difficult, but should be performed on a rou-

tine basis. The operator chassis is zinc plated, but some environments may speed corrosion of this plating.

Schedule regular maintenance and look for the following:

• Assess that the drive belt has the proper tension. Check for drive belt wear. Fraying edges or missing teeth indicate

that the drive belt needs to be replaced.

• Check for signs of rust. If any areas of rust are found, reduce the spread of corrosion by treating the areas with a rust

inhibitor.

• Replace worn-out batteries.

• On the StrongArmPark DC 14 spring assembly, apply grease to zerk fitting and upper rod end.

d

rIve

B

elt

t

ensIon

and

a

lIgnment

Proper drive belt tension is important for prolonging the life of the drive belt and maintaining the superior

performance of the operator. To check the drive belt tension, take the following steps:

1. Remove the Front Access Panel.
2. Turn off the AC and DC power switches.
3. Remove the StrongArmPark DC top cover and drive belt cover.
4. Check to make sure the pulleys are aligned vertically.

DC and AC
power switches

Top cover

Drive belt
cover

Front access panel