Every StrongArmPark DC operator comes equipped with a breakaway arm

bracket, which lessens damage to the operator and reduces the cost of arm

replacement due to vehicle hits.

For more information about installing the breakaway arm bracket, review the

StrongArmPark DC Installation Instructions.

I

nHerent

e

ntrapment

s

ensor

(Ies)

The StrongArmPark DC provides an added feature in its inherent entrapment sensor (IES). While closing, if the

IES is tripped twice within a specific period of time, it enters safe mode. The operator stops barrier arm travel and

reverses full open.

The adaptive IES software monitors the average running motor current while the barrier arm is in motion and

reverses the arm when the current exceeds an automatically self-adapting average. This unique adaptability is

handled internally based on the length and weight of the barrier arm. The IES sensitivity requires no adjustments.